GD High Effiency Particulate Air ( HEPA ) filters are the most efficient air filters commercially available. They have broad application in cleanrooms and other areas requiring the very highest levels of contamination control including :
GD filters are available in a variety of contruction materials and cell side configurations to fit and competitive framing systems or sending design.Refer to the section on selection data for a complete list of options.
5 7/8 " deep - 125 FPM @ 1.0 in. w.g
11 1/2 "deep - 125 FPM @ 1.0 in. w.g
Efficiencies : 99.97% and 99.99% minimum efficiency on 0.3 micrometer particles.
Additional efficiency level including ULPA available. Higher efficiencies up to 99.999995% on . 10 to 20um particles, available with our DIMPLEPLEAT and GD mini-pleat filters.
24" x 24" x 111/2 " deep - 2000 CFM @ 1.4 in. w.g.
Efficiencies: 99.97% and 99.99% minimum efficiency on 0.3 micrometer particles.
High Capacity GD filters are designed to handle higher airflow than a standard HEPA filter. This offers greater operating flexbility and cost savings.
Filters that pass the overall efficiency test may still have minute pinhole leaks GD filters can be factory scanned to ensure there are no pinhole leaks.Scanning detects these leaks, which are repaired before the filter is released for shipment.
We use a proprietary static scan test with a challenge aerosol of non-toxic, polyfunctional alcohol that leaves no residue on the media. For pharmaceutical and those applications requiring PAO. We offer scanning with this material using a light scattring photometer.
Two methods of overall efficiency testing used :
PAO TEST - This has been the industry standard for many years. It is conducted using a light scattering photometer. The filter is challenged with Polyalphaolefin ( PAO ).
By measuring the upstream and downstream concentration filter efficiency can be calculated LASER TEST - The filter is tested with a laser spectrometer using polystrene latex ( PSL ) spheres. Filter efficiency is determined by comparing the upstream and downstream concentrations. Efficiencies down to 0.10 micrometers can be determined.
UL Classified
GD filter are UL Classified. Testing is performed according to UL. Standard 900 and ULC S111 ( except those made with non fire-retardant wood cell sides ).
UL 586
This standard ensures that each filter is individually tested at the factory. Addtiionally, representative filters are tested by UL to ensure that they provide HEPA level filtration, after being subjected to the following conditions.
UL also subjects the filter to a spot flame test ( 1750oF / 954oC ). A numbered UL label certifying that the filter meets Standard 586 is then applied to the filter.
GD filters are constructed with stainless steel or aluminium cell sides and are available for
400o ( 204oC ) - Stainless Steel or Aluminium
500oF ( 260oC ) - Stainless Steel or Aluminium Cell Sides, Red RVT Silicone Board.
750oF ( 399oC ) - Stainless Steel or Aluminium Cell Sides, Black Cement Bond.
Two methods of overall efficiency testing used :
GD SIDE ACCESS FILTERS
GD Filters are constructed with a flange at the top and bottom for installation into earlier models of side access housings. The filters are available with wood or metal cell sides.
GD Filters are available to comply with military and nuclear specifications ( ASME AG-1 ) requiring special cell side material, radiation resistant media, rabbeted joints, special testing and special packaging and marking.
Comparison | STANDARD GD 24" x 24" x 111/2" | HIGH CAPACITY GD HCX 24" x 24" x 111/2" |
---|---|---|
Rated AirFlow Capacity | 2000 SCFM | |
@ 1.4 in. w.g. ( 350 Pa ) initial resistance | ( 3400 m3/hr ) | |
Rated AirFlow Capacity | 1000 SCFM | 1500 SCFM |
@ 1.0 in'. w.g. ( 250 Pa ) initial resistance | ( 1700 m3/hr ) | ( 2550 m3/hr ) |
Service Life Ratio | 1.0 | 2.0 |
( 1000 SCFM ( 1700 m3/hr ) |
GD 24" x 24" x 111/2
Initial Resistance vs. Airflow Capacity
GD Filters are available In a wide variety of standard sizes and construction material. Special sizes can be fabricated or speacial material used for unique requirements.
There are twelve criteria encompassing materials and performance that go into the makeup of filter. Careful selection on the right combination will result in the filter that best meets the needs of your application.
Sizes from 8" x 8" to 36" x 72" Our sizes are listed wth the height dimension first, followed by the width, then depth. Minimum Efficiency
99.97% - 0.3um
99.99% - 0.3um
99.999% - 0.3um
GD filters can be scan tested to eliminate pinhole leaks.
Waterproof, fire-retardant microglass.Waterproof,fire-retardant, radiation resistant microglass.
Plywood
Fire Retardant Plywood
Particle Board
Aluminium
Vinyl Coated Aluminium
Polyurethane Elastomer
Silicone
Black Cement
Neoprene Expanded Rubber
Silicone
Urethane
None
One Side
Both Sides
4 x 4 Mesh Hardware Cloth
Glavanized Steel
Stainless Steel
None
One Side
Both Sides
Numbered UL certification label to be applied.